1025 : Equipment Profile

eProcess Sheets Due:

Tyrion Lannister
40%
Jon Snow
100%

Work Order #

0004663318

Min Scan Date

05/11/2017

Last Run

05/12/2017

Stub Flag

No

Order # Procedure id / Description Status PAYCODE Date
WO-0004663318 12000G / 12000 MILE INSPECTION (GILLIG) PLAN 5195 05/01/2017
WR-0003471234 Fix Handicap decals on seats behind driver's side      
Description: Gillig G0900 2002 14L
DOB: 04/29/2002
Vehicle Life, Days: 5,490
Vehicle Life, Miles: 458,199

Engine

Equipment #: EM280-055866
Serial #: 35055866
Item #: 1434380
Attachment Date: 04/29/2002
Miles since DOB: 460,995

Lift

Equipment #: L3870-039
Serial #: 3870-039
Item #: 1696978
Attachment Date: 04/29/2002
Miles since DOB: 460,095

Transmission

Equipment #: TD864-844673
Serial #: 844673
Item #: 2383920
Attachment Date: 11/30/2011
Miles since DOB: 67,987
Date W/O# STATUS PROC ID Comments
05/17/2017 0004740160 COMP QRC bus changed by: call operator
shop request for maintenance.

See w.o. 4740150

05/10/2017 0004734037 COMP JRT left rear axle seal leaking

replaced axle gasket, filled differential - cleaned wheel. by rs

05/06/2017 0004729899 COMP QRC bus changed by: s98 operator
op rpts possible urine on the floor in the rear seat area, op side of bus.
em s98 for bc.

disinfected, mopped rear of bus. ok fs by rs

05/05/2017 0004727747 COMP PRC op reports check engine, stop engine and audible alarm.

pulled codes 1922, one step went active. r&r doc & dpf. doc/dpf needs to be reset. These were just done a month ago.
coolant full - bus won't stay running. towed back to emg. axles installed, rear end needs filled. code 1922 in ecm. perf. reset & regen, test drove & reset, removed doc/dpf, insp. & found no debris. installed new pressure sensor module and dpf. 3597 set.
test drove bus, connected computer, no codes found in ecm. no lights on in the bus. ok for service.

05/04/2017 0004729035 COMP CRT coolant leak at valve by defroster heater core

r & r valve.
by gm

04/21/2017 0004680801 CLOS CLEAN general clean
04/13/2017 0004678302 CLOS ACA annual ac inspection